6. FUEL SYSTEM
6-7
Auto By-Starter
Inspection
Turn off engine and waiting for over 10 minutes for
cooling.
Check resistance across the two terminals of the
auto by-starter.
Resistance value: Max. 10Ω (Measured after
engine stopped for more than 10 minutes)
Replace the auto starter with a new one if
resistance value exceeds standard.
Remove carburetor allow it to cool off for 30
minutes.
Connect a pressure tester from air pump.
Connect by-starter circuit.
Pump compressed air to the circuit.
Replace the auto by-starter if the circuit clogged.
Connect battery posts (12V) to starter’s
connectors. After 5 minutes, test the by-starter
circuit with compressed air. If air flows through the
circuit, then, replace the starter.
Removal
Remove fixing plate screw, and then remove the
plate and auto by-starter from carburetor.
Valve inspection
Check if auto by-starter and valve needle for
damage or wear out.
Installation
Install auto by-starter to the bottom of carburetor
body.
Install fixing plate to the upper groove of auto
by-starter, and install its flat surface to carburetor.
Install screw and tighten it.
Auto by– starter
Screw ×2
Needle
Seal