097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 109
Chapter 2 TL1 Command Syntax and Description
Retrieve Log (RTRV-LOG)
Retrieve Log (RTRV-LOG)
This command displays all events in the event log in chronological order (first in,
first out). The event log contains the last 500 alarmed and non-alarmed events.
This command has a default access level of USER.
Syntax
RTRV-LOG:[<tid>]:[<aid>]:[<ctag>][::<keyword>,[index],[,count][,[start date],
[stop date]];
Note: Alarms with an alarm level set to NONE are not stored in the
event log.
Parameter Value
Description
See Table 2-22 for <keyword> descriptions.
<aid> ALL (or null) Retrieves events containing any aid.
IMC Retrieves events with an aid field of IMC.
IOC Retrieves events with an aid field of IOC.
IOCm Retrieves events with an aid field of IOCm, where:
m = “1” for the slot marked “IOC 1" on the main shelf
m = “2” for the slot marked “IOC 2" on the main shelf
GPS Retrieves events with an aid field of GPS.
PRS Retrieves events with an aid field of PRS.
INPp Retrieves events with an aid field of INPp, where:
p = “1” for the input marked INP 1 on the Input
Connector module
p = “2” for the input marked INP 2 on the Input
Connector module
OUTg Retrieves events with an aid field of OUTg, where:
g = “A” for the group marked “A” on the main shelf
g = “B” for the group marked “B” on the main shelf
g = “C” for the group marked “C” on the main shelf
g = “D” for the group marked “D” on the main shelf
RTMg Retrieves events with an aid field of RTMg, where:
g = “A” for the group marked “A” on the main shelf
g = “B” for the group marked “B” on the main shelf
g = “C” for the group marked “C” on the main shelf
g = “D” for the group marked “D” on the main shelf
E422g Retrieves events with an aid field of E422g, where:
g = “A” for the group marked “A” on the main shelf
g = “B” for the group marked “B” on the main shelf
g = “C” for the group marked “C” on the main shelf
g = “D” for the group marked “D” on the main shelf

Table of Contents

Other manuals for Symmetricom TimeProvider 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1000 and is the answer not in the manual?

Symmetricom TimeProvider 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1000
CategoryClock
LanguageEnglish

Related product manuals