140 TimeProvider TL1 Reference Guide 097-58001-01 Revision E – September 2006
Table A-2. System Commands
Command Description
Copy Memory (CPY-MEM), on
page 36
Saves a module’s Istate in another module’s flash memory
Retrieve Date (RTRV-DAT), on
page 99
Retrieves the system date, time, and local offset
Edit Date (ED-DAT), on page 44 Changes the system date and time
Retrieve Equipment
(RTRV-EQPT), on page 101
Retrieves currently provisioned equipment parameters
Edit Equipment (ED-EQPT), on
page 45
Used to provision equipment parameters
Retrieve Sync (RTRV-SYNC), on
page 123
Retrieves equipment parameters associated with provisioning of
the synchronization interfaces for the system inputs and outputs
Edit Sync (ED-SYNC), on page 55 Changes factory settings and input and output port parameter
settings
Retrieve Circuit Identification
(RTRV-CKTID), on page 84
Retrieves the circuit ID for the specified input or output
Edit Circuit Identifier (ED-CKTID),
on page 41
Changes the circuit ID for the specified input or output
Retrieve Attribute (RTRV-ATTR),
on page 76
Retrieves the alarm level set for a specified alarm
Initialize Event Log (INIT-LOG), on
page 66
Clears the event log on the IMC module
Retrieve Log (RTRV-LOG), on
page 109
Retrieves all events in the event log
Initialize System (INIT-SYS), on
page 67
Initializes the specified module, or the system
Retrieve System Mode
(RTRV-SYS-MODE), on page 125
Retrieves the TimeProvider’s currently provisioned system
operating mode
Set System Mode
(SET-SYS-MODE), on page 134
Provisions the TimeProvider system’s operating mode to SSU,
SUB, or PRR
Operate Alarm Cutoff
(OPR-ACO-ALL), on page 69
Deactivates (opens) the minor, major, and critical audible alarm
relays
Set Source Identifier (SET-SID),
on page 133
Provisions the TimeProvider system’s source identifier (SID)
Retrieve Alarm Condition
(RTRV-ALM), on page 73
Retrieves information on currently active alarms