097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 113
Chapter 2 TL1 Command Syntax and Description
Retrieve Network Equipment Type (RTRV-NETYPE)
Retrieve Network Equipment Type (RTRV-NETYPE)
This command retrieves the network equipment (NE) type from the unit, in this
case, “TimeProvider.”
This command has a default access level of NONE.
Syntax
RTRV-NETYPE:::[<ctag>];
Example
To retrieve the NE type from the TimeProvider:
Input
RTRV-NETYPE:::TP1000;
Normal Response
TP-SSU 05-02-10 13:37:39
M TP1000 COMPLD
"
TimeProvider
"
;
Autonomous Message
None