Chapter 2 TL1 Command Syntax and Description
Retrieve Attribute (RTRV-ATTR)
78 TimeProvider TL1 Reference Guide 097-58001-01 Revision E – September 2006
Example
To display the current level set for the IMC module’s IOC1COMM alarm:
Input
RTRV-ATTR::IMC:TP1000::IOC1COMM;
Response Example
TP-SSU 05-02-10 13:37:39
M TP1000 COMPLD
"IMC:IOC1COMM,MN"
;
Autonomous Message
None
Table 2-11. RTRV-ATTR Output Fields
Field Description
alarm id The identifier of the alarm for which the level is displayed.
Note: See Table B-1 for the possible alarm identifiers.
alarm level The level for the specified alarm. The alarm level can be CR (critical alarm), MJ
(major alarm), MN (minor alarm), NA (non-alarm event), NR (not reported), or CL
(clearing event).