097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 27
Chapter 2 TL1 Command Syntax and Description
Activate Feature (ACT-FEATURE)
Activate Feature (ACT-FEATURE)
This command enables the specified feature in the TimeProvider. Once the feature
has been enabled, it cannot be disabled.
This command has a default access level of ADMIN.
Syntax
ACT-FEATURE:[<tid>]:<fid>:[<ctag>]::<key>;
Example
To activate the NTP feature using the Symmetricom-supplied <key> parameter:
Input
ACT-FEATURE::NTP:TP1000::"Symmetricom-Key";
Normal Response
TP-SSU
05-02-10 13:35:56
M TP1000 COMPLD
;
Autonomous Message
TP-SSU 05-02-10,13:35:56
A 2528 REPT EVT
"IMC,EQPT:FEATURE,TC,05-02-10,13-35-56,,,,:\"SYSTEM FEATURE HAS BEEN
ACTIVATED, NTP\""
;
Parameter Value Description
<fid> NTP The name of the feature to be activated.
<key> The key to enable the feature. This can be up to 20
case-sensitive characters, and must be enclosed in quotes.
Contact your Symmetricom representative to obtain the key.

Table of Contents

Other manuals for Symmetricom TimeProvider 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1000 and is the answer not in the manual?

Symmetricom TimeProvider 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1000
CategoryClock
LanguageEnglish

Related product manuals