097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 81
Chapter 2 TL1 Command Syntax and Description
Retrieve Built-In Self Test (RTRV-BIST)
Retrieve Built-In Self Test (RTRV-BIST)
This command displays all currently active faulted built-in self test information for
either the IMC or IOC or both.
This command has a default access level of USER.
Syntax
RTRV-BIST:[tid]:<aid>:[<ctag>];
Normal Response
IMC
<cr><lf><lf>
sid date time<cr><lf>
M ctag COMPLD<cr><lf>
"IMC BIST"<cr><lf>
"<IMC condscr>"<cr><lf>*
;
IOC#
<cr><lf><lf>
sid date time<cr><lf>
M ctag COMPLD<cr><lf>
"IOC# BIST"<cr><lf>
"<IOC# condscr>"<cr><lf>*
;
Parameter Value Description
<aid> IMC Displays the currently active faulted built-in self test information
for the Information Management Card (IMC).
Note: See Table 2-13 for <condscr> descriptions.
IOCm Displays the currently active faulted built-in self test information
for the Information Management Card (IOC).
m = “1” for the slot marked “IOC 1" on the main shelf
m = “2” for the slot marked “IOC 2" on the main shelf
Note: See Table 2-13 for <condscr> descriptions.
Note: An asterisk (*) indicates that multiple lines could be listed; all
active alarm conditions are shown on separate lines.

Table of Contents

Other manuals for Symmetricom TimeProvider 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1000 and is the answer not in the manual?

Symmetricom TimeProvider 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1000
CategoryClock
LanguageEnglish

Related product manuals