Chapter 2 TL1 Command Syntax and Description
Initialize Event Log (INIT-LOG)
66 TimeProvider TL1 Reference Guide 097-58001-01 Revision E – September 2006
Initialize Event Log (INIT-LOG)
This command clears the event log on the IMC module.
This command has a default access level of ADMIN.
Syntax
INIT-LOG:[<tid>]:<aid>:[<ctag>];
Example
To clear the event log on the IMC module:
Input
INIT-LOG::IMC:TP1000;
Normal Response
TP-SSU
05-02-10 13:35:56
M TP1000 COMPLD
;
Autonomous Message
TP-SSU
05-02-10 13:35:56
A 2563 REPT EVT
"IMC,EQPT:INITLOG,TC,05-02-10,13-35-56,,,,:\"EVENT LOG HAS BEEN CLEARED\""
;
Parameter Value Description
<aid> IMC The command’s effect is on the Information Management
Card module.