EasyManuals Logo

Symmetricom TimeProvider 1000 Reference Guide

Symmetricom TimeProvider 1000
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #137 background imageLoading...
Page #137 background image
097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 137
Chapter 2 TL1 Command Syntax and Description
Set Threshold (SET-TH)
Example
To set the system’s operating mode to Subtending:
Input
SET-TH:::TP1000::;
Normal Response
TP-SSU
05-02-10 13:35:56
M TP1000 COMPLD
;
Autonomous Message
TP-SSU
05-02-10 13:35:56
A 1166 REPT EVT
"GPS,EQPT:THRCHG,TC,05-02-10,13-35-56,,,,:\"PM THRESHOLD HAS CHANGED,
FFOFF-60\""
;
FFOFF-60 100 to 10000000
(ps/s)
Fractional Frequency Offset threshold for 60 second
calculation period, defined in ps per s
10 000 000
SLIPCHG 0 to 255 Maximum number of slips that can occur in a
24-hour period
4
Table 2-36. Mask Table
MTIE-1 MTIE-5 MTIE-10 MTIE-50 MTIE-100 MTIE-500 FFOFF-60
DEFAULT 10 000 50 000 100 000 500 000 1 000 000 5 000 000 10 000 000
GPS-R 150 150 150 150 150 155 50 000
PRS 10 10 12 25 39 155 1000
DS1 302 312 325 325 550 1002 12 000
OCN 600 1000 1000 1000 1000 1002 370 000
PRC 25 25 25 25 39 155 1000
TYPEI 750 750 1000 2000 2000 2000 2900
TYPEII 302 312 325 425 1000 1000 1000
Table 2-35. SET-TH – Keywords and Values for all <aids> (Continued)
<keyword> <value> Description Default

Table of Contents

Other manuals for Symmetricom TimeProvider 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1000 and is the answer not in the manual?

Symmetricom TimeProvider 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1000
CategoryClock
LanguageEnglish

Related product manuals