Chapter 2 TL1 Command Syntax and Description
Retrieve Log (RTRV-LOG)
112 TimeProvider TL1 Reference Guide 097-58001-01 Revision E – September 2006
Example
To retrieve all alarmed and non-alarmed events which have an aid field of IOC1:
Input
RTRV-LOG:::IOC1:TP1000::ALL;
Response Example
TP-SSU 05-02-10 13:37:39
M TP1000 COMPLD
"IOC1,EQPT:MN,CLKWARM,SA,05-02-10,12-00-10:\"CLOCK ENTERED WARM-UP MODE\""
"IOC1,EQPT:CL,CLKWARM,SA,05-02-10,12-07-37:\"CLOCK EXITED WARM-UP MODE\""
"IOC1,EQPT:MJ,CLKFREE,SA,05-02-10,12-07-37:\"CLOCK ENTERED FREE-RUN MODE\""
"IOC1,EQPT:NA,IOCMODE,NSA,05-02-10,12-07-40:\"IOC MODE IS, ACTIVE\""
"IOC1,EQPT:MJ,CLKFREE,SA,05-02-10,12-00-01:\"CLOCK ENTERED FREE-RUN MODE\""
"IOC1,EQPT:CL,CLKFREE,SA,05-02-10,12-00-01:\"CLOCK EXITED FREE-RUN MODE\""
"IOC1,EQPT:CR,CLKFREE,SA,05-02-10,12-00-01:\"CLOCK ENTERED FREE-RUN MODE\""
;
Autonomous Message
None
condscr The description of the alarm or event. It is a quoted text string, preceded with the “\”
escape character.
Note: Table C-2 shows all of the possible TimeProvider event descriptions (event
condition strings), and Table B-2 shows all of the possible TimeProvider alarm and
clearing alarm condition strings.
Table 2-24. RTRV-LOG Alarm Output Fields (Continued)
Field Description

Table of Contents

Other manuals for Symmetricom TimeProvider 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1000 and is the answer not in the manual?

Symmetricom TimeProvider 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1000
CategoryClock
LanguageEnglish

Related product manuals