097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 119
Chapter 2 TL1 Command Syntax and Description
Retrieve PM (RTRV-PM)
Input
RTRV-PM::IOC1-GPS:TP1000::PHASE;
Response Format
<cr><lf><lf>
sid date time<cr><lf>
M ctag COMPLD<cr><lf>
"IOCm-INPp:PHASE,<monval>,<vldty>,<sampledat>,<sampletim>"<cr><lf>
"<.>,<.>,<.>,<.>,<.>,<.>,<.>,<.>,<.>,<.>"<cr><lf>
"<.>,<.>,<.>,<.>,<.>,<.>,<.>,<.>,<.>,<.>"<cr><lf>
Response Example
TIMEPROVIDER 05-02-10 13:37:39
M TP1000 COMPLD
"IOC1-GPS:PHASE,93.7,COMPL,05-02-03,20-15-32"
"1.8,0.8,-1.4,-1.9,-0.1,-1.8,-2.1,0.8,1.5,0.9"
"0.4,1.4,1.1,-2.1,-1.9,0.1,-1.9,-2.0,0.6,0.6"
"-0.2,0.2,1.5,1.1,0.9,1.8,1.0,0.3,0.2,0.0"
"-0.6,0.1,0.0,0.5,1.4,0.2,-0.2,0.0,-0.9,-1.1"
"-0.6,-0.3,-0.6,-0.9,-0.9,-0.9,-0.8,-1.2,-0.6,4.1"
"2.9,-0.2,1.7,1.8,-0.8,-1.7,-1.3,-1.5,-1.5,0.2"
;
Example
To retrieve PHASE1S data:
Input
RTRV-PM::IOC1-GPS:TP1000::PHASE1S;
Response Format
<cr><lf><lf>
sid date time<cr><lf>
M ctag COMPLD<cr><lf>
"IOCm-INPp:PHASE1S,<manval>,<vldty>,<sampledat>,<sampletim>"<cr><lf>
"<.>,<.>,<.>,<.>,<.>,<.>,<.>,<.>,<.>,<.>"<cr><lf>
"<.>,<.>,<.>,<.>,<.>,<.>,<.>,<.>,<.>,<.>"<cr><lf> <cr><lf><lf>
Notes:
To select a specific set of accumulated phase data from the previous
24 hours, enter the start date (startdat), start time (starttim),
stop date (stopdat), and stop time (stoptim).
If any startdat or starttim combination is null or outside of the
previous 24 hour window, the current 1-Hour 1-Second Phase data
(1 nS resolution) is displayed.
The first line of the record has the first measurement requested, the
timestamp (<sampletim>, <sampledat>) are associated with this
measurement.