Appendix B Alarms
146 TimeProvider TL1 Reference Guide 097-58001-01 Revision E – September 2006
CLKWARM The local oscillator on
the specified IOC is in
Warm-up mode.
EQPT SA IMMED NO MN MN MN
SYNTHEOR The synthesizer
generating the modules
stable output frequency
has reached the defined
End-of-Range for the
type of oscillator used
on the IOC.
EQPT SA IMMED NO MJ MJ MJ
<aid> = GPS
ANTCOMM Loss of communications
to antenna
T1 NSA IMMEDNO MNMNMN
GPSPOS The GPS Antenna’s
position is unknown
T1 NSA IMMED YES NA NA NA
GPSPWR TimeProvider power to
TPIU is either high or
low.
T1 NSA IMMEDNO MNMNMN
GPSSYS GPS System is
indicating an error with
BIST (at startup)
TRAIM, and/or
UTC/ephemeris data.
T1 NSA IMMED YES MN MN MN
GPSTRK The GPS Engine is not
tracking any satellites.
T1 NSA IMMED YES MN MN MN
INPDISQ The specified input was
Disqualified or Qualified
as a possible system
reference. The fault
condition must be
continuously present for
the Fault Delay Time
(FLTDELAY) before
disqualifying the input
as a possible reference.
After INPDISQ is set the
alarm clears when the
input signal is fault free
for the Clear Delay Time
(CLRDELAY).
T1 NSA FLT
DELAY
YES MN MN MN
Table B-1. Alarms (Continued)
Alarm ID
or
CONDTYPE
Alarm Condition
Description
AID
Type
Service
Affecting
Error
Delay
Default
Error
Delay
Editable
Alarm Default
Level
SSU PRS SUB

Table of Contents

Other manuals for Symmetricom TimeProvider 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1000 and is the answer not in the manual?

Symmetricom TimeProvider 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1000
CategoryClock
LanguageEnglish

Related product manuals