097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 161
Appendix C Events
INPREF The specified input was
selected as system
reference. The possible
references includes PRS,
INP1, or INP2. GPS is
reference in PRR mode
only
EQPT PRS GPS | PRS | INP1 | INP2
IOCMODE When an IOC becomes
the Active it generates an
event.
EQPT ACTIVE ACTIVE | STANDBY
IOCSTATE The specified IOC
module was inserted into
the system. The module
is automatically
Placed-In-Service.
EQPT INSRV INSRV – In Service
The User has specified
the IOC module be taken
“Out of Service”. OOSRV
prevents the module from
generating alarms or
being provisioned or
queried for provisioned
settings, etc.
EQPT INSRV OOSRV – Out of Service
RESET When the IOC is
commanded to reset, it
generates an event
indicating that it is being
restarted.
Prior to restarting all
alarms associated with
the specified IOC is
cleared. Prior to
restarting, if the IOC is
the Active IOC it is
successfully placed in
Standby mode.
EQPT NA NA
SYSMODE Configures the systems
mode of operation.
EQPT SSU
SSU – Sync Supply Unit mode
of operation
SUB – Subtending TSG mode
of operation
PRR – Primary Reference
Receiver mode of operation
Table C-1. Event Identifiers (Continued)
Event ID
or
CONDTYPE
Event Description
AID
TYPE
Default Value Value Description

Table of Contents

Other manuals for Symmetricom TimeProvider 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1000 and is the answer not in the manual?

Symmetricom TimeProvider 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1000
CategoryClock
LanguageEnglish

Related product manuals