097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 163
Appendix C Events
INSTATE The state of the input
ports used by the system
T1 ENABLE DISABLE – Disabled inputs,
associated active alarms are
cleared.
ENABLE – Enabled inputs, are
available as system reference.
MONITOR – Allows the input
to be monitored for
performance and signal faults,
but cannot be selected as
reference input.
PMCLR Allows the user to Clear
the gathered
Performance Data that is
stored in the IMC
module.
EQPT NA NA
PRIORITY Allows the user to
provision the priority of
the input using
T1 1 (GPS)
1 (PRS)
2 (INP1)
3 (INP2)
1 = Highest
2
3
4 = Lowest
RQLEVEL The Received Quality
Level represents the
received SSM on INP1 or
INP2, this allows
notification of changing
SSMs
T1 2 1 = PRC/PRS
2 = UNK/STU
3 = TYPE II/ST2
4 = TYPE I
5 = TYPE V/TNC
6 = TYPE III/ST3E
7 = TYPE IV/ST3
8 = 811OPT3/SMC
9 = DUS
QLEVEL Allows the user to
provision the Quality
Level of the input.
T1 2 1 = PRC/PRS
2 = UNK/STU
3 = TYPE II/ST2
4 = TYPE I
5 = TYPE V/TNC
6 = TYPE III/ST3E
7 = TYPE IV/ST3
8 = 811OPT3/SMC
9 = DUS
SSMBIT Allows the user to
provision E1 (CAS/CCS)
SSM bit position to allow
the input to determine to
proper bit to read the
SSM on.
T1 8 4 | 5 | 6 | 7 | 8
Table C-1. Event Identifiers (Continued)
Event ID
or
CONDTYPE
Event Description
AID
TYPE
Default Value Value Description