EasyManuals Logo

Symmetricom TimeProvider 1000 Reference Guide

Symmetricom TimeProvider 1000
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 53
Chapter 2 TL1 Command Syntax and Description
ED-EQPT for NTP Parameters
Syntax
ED-EQPT:[<tid>]:NTP:[<ctag>]::KEYGEN,<func>,<keyid>[,<key>];
Example
To add an NTP authentication key:
Input
ED-EQPT::NTP:TP1000::KEYGEN,ADD,ABC...XYZABCDEF,1024;
Normal Response
TP-SSU 05-02-10 13:35:56
M TP1000 COMPLD
;
Autonomous Message
TP-SSU 05-02-10 13:35:56
A 2537 REPT EVT
"NTP,EQPT:SERVER,TC,05-02-10,13-35-56,,,,:\"NTP AUTHENTICATION HAS
CHANGED\""
;
<keyword> <value> Description Default
FUNC ADD | DELETE
| MODIFY
Key to be added, deleted, or modified NA
KEY 32-character
ASCII value
Authentication key Null
KEYID 1 to 65534 The Authentication identification value 1

Table of Contents

Other manuals for Symmetricom TimeProvider 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1000 and is the answer not in the manual?

Symmetricom TimeProvider 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1000
CategoryClock
LanguageEnglish

Related product manuals