097-58001-01 Revision E – September 2006 TimeProvider TL1 Reference Guide 53
Chapter 2 TL1 Command Syntax and Description
ED-EQPT for NTP Parameters
Syntax
ED-EQPT:[<tid>]:NTP:[<ctag>]::KEYGEN,<func>,<keyid>[,<key>];
Example
To add an NTP authentication key:
Input
ED-EQPT::NTP:TP1000::KEYGEN,ADD,ABC...XYZABCDEF,1024;
Normal Response
TP-SSU 05-02-10 13:35:56
M TP1000 COMPLD
;
Autonomous Message
TP-SSU 05-02-10 13:35:56
A 2537 REPT EVT
"NTP,EQPT:SERVER,TC,05-02-10,13-35-56,,,,:\"NTP AUTHENTICATION HAS
CHANGED\""
;
<keyword> <value> Description Default
FUNC ADD | DELETE
| MODIFY
Key to be added, deleted, or modified NA
KEY 32-character
ASCII value
Authentication key Null
KEYID 1 to 65534 The Authentication identification value 1