Table 4
-
1: Front Panel controls and indicators
Nu
m
ber
Control/Indicator
Description
Section
1
VOLTAGE control
High resolution rotary encoder for adjusting the Output
Voltage. Also adjusts the OVP/UVL levels and selects the
A
d
dress
5.2.1
5.3.1
5.4.1
7.2.2
2
VOLTAGE indicator
Green LED, lights for constant
-
Voltage mode oper
a
tion.
3
VOLTAGE display
4 digit, 7
-
segment LED display. Normally displays the ou
t-
put voltage. When the PREV button is pressed, the display
indicates the p
rogrammed setting of the output voltage.
When the OVP/UVL button is pressed, the Vol
t
age display
indicates the OVP/UVL se
t
ting.
4
CURRENT display
4 digit, 7 segment LED display. Normally displays the ou
t-
put current. When the PREV button is pressed, the d
isplay
ind
i
cates the programmed setting of output current.
5
CURRENT indic
a
tor
Green LED, lights for Constant
-
Current mode o
p
eration
6
CURRENT control
High resolution rotary encoder for adjusting the Output
Current. Also selects the Baud
-
Rate of the co
mmunic
a
tion
port.
5.2.2
7.2.4
7
OUT button
Main function:
Output ON/OFF control. Press OUT to set
the output On or Off. Press to reset and turn On the ou
t
put
after OVP or FOLD alarm events have occurred.
Au
x
iliary
function:
Selects between “Safe
-
Start
and “Auto
-
Restart”
modes. Press and hold OUT button to toggle b
e
tween
“Safe
-
Start” and “Auto
-
Restart”. The VOLT display will c
y-
cle between “SAF” and “AUT”. Releasing the OUT button
while one of the modes is di
s
played, selects that mode.
5.6
5.11
8
OUT i
ndicator
Green LED, lights when the DC output is enabled.
9
REM/LOC button
Main function
: Go to local. Press REM/LOC to put the unit
into Local (REM/LOC button is disabled at Local Lockout
mode).
Auxiliary function:
Address and Baud Rate setting. Pre
ss
and hold REM/LOC for 3 sec. to set the Address with the
VOLTAGE encoder and the Baud Rate with the CURRENT
encoder.
7.2.5
7.2.2
7.2.4
10
REM/LOC indicator
Green LED, lights when the unit is in Remote mode.
11
FOLD button
Foldback protection control
.
-
Press FOLD to set Foldback protection to On.
-
To release Foldback alarm even, press OUT to e
n
able the
output and re
-
arm the protection.
-
Press FOLD again to cancel the Foldback protection.
5.5
12
FOLD indicator
Green LED, lights when Foldback protectio
n is On.