Down in the Master Supply and up in all Slave Supplies.
Connect a short between J1
12 in all Slave Supplies.
25 of the Master Supply to J1
10 of all Slave Supplies.
15 of the ‘First’ Slave Supply.
16 of the ‘First’ Slave Supply to J1
15 of the ‘Second’ Slave Supply (if any)
16 of the ‘Second’ Slave Supply to J1
15 of the ‘Third’ Slave Supply (if any)
Select Local or Remote sense
2. Setting the units as Master or Slave
a) Depress and hold the FINE button for 3 seconds. The Master/Slave configuration will be
on the Current Display. Rotate the CURRENT encoder to obtain the desired mode. Refer to Table 5
for the CURRENT display and modes of operation.
Master supply with 1 Slave supply
Master supply with 2 Slave supplies
Master supply with 3 Slave supplies
4: Setting mode of operation
b) When the desired configuration is obtained, depress and release the FINE button or wait approx. 5
Slave units default operation
a) When a unit is programmed to Slave mode it enters the Remote mode with Local Lockout. In this
mode, the front panel controls are disabled to prevent accidental setting change (refer to Sec. 7.2.7 for
units parameters will automatically set the following:
*Output voltage to approximate. 102% of rated output voltage.
*Programmed Current to zero.
*OVP to its maximum value
c) The Master and Slave modes are stored in the power supply EEPROM when the AC power is turned
off. The system will return to the Master/Slave mode upon re
d) Master unit does nto display actual total current of all the units
4. CURRENT display accuracy
In the advanced parallel mode, the Master unit
does not display actual total current of all units in parallel.
this method, the CURRENT display accuracy is 2% +/
1 count. In cases that higher accuracy is r
is recommended to use the basic parallel o
To release units from Slave mode
Slave units can be released using the following procedure:
a) Depress FINE button for 3 seconds. The Master/Slave configuration will be displayed on the
b) Select H1 mode using the CURRENT encoder.
c) Depress FINE button again or wait 5 seconds.
d) Turn the AC power Off to store the new setting.
e) After exiting from Slave operation the unit’s parameters will be set to: