Send (0xC0 + Address) (1 byte binary
send 2 times sequentially). The suppl
the last message sent. Note that the supply does not have to be the active addressed su
This command will not execute if another command is being processed.
Note that Single byte commands do not load data into the supply’s data output bu
this command will not cause the supply to retransmit data obtained from any previous Si
Test if MD Mode is Installed
Send AA Hex followed by the address of the supply in binary. If not installed, the supply will
If installed, the supply will return a ‘0’.
Addressed commands without response
Send (0xE0 + Address) (1 byte binary
send 2 times sequentially). The supply will stop re
sending SRQ. If Enable SRQ retransmission is active, it will remain a
enable SRQ with out reading/clearing the SEVE Register
Send A5 Hex followed by the address of the supply in binary and new SRQ’s generated by
new events in the Fault Event will be enabled without reading and clearing the Status Event
l events previously recorded in the Fault Event Register must have been se
viced by the user’s software prior to this command to take affect.
Set supplies into MD Mode
Disable retransmission of SRQs by
Enable retransmission of SRQ
Enable the FLT bit in the SENA
All supplies will halt transmission and
Non destructive read of all register.
x xxxx is the address of the supply in