83
-
530
-
000 Rev
G
60
Re
-
enable SRQ
Byte 1
1010 0101
Byte 2
xxxx xxxx
None
Re
-
enable SRQ without reading or
clearing the SEVE Register. xxxx
xxxx is the address of the supp
ly in
binary. Works only in MD Mode.
Print Power On
Time
Byte 1
1010 0110
Byte 2
xxxx xxxx
Power On time
in minutes
Read the time the supply is active
under AC Power. xxxx xxxx is the
address of the supply in binary. R
e-
turns a 32 Bit integer as 8 Hex byte
s.
A ‘$’ sign is appended to the data
followed by a 2 byte check
-
sum. A
total of 11 bytes are returned.
Retransmit last
message
110x xxxx
Last message
Retransmit last response from a
command. x xxxx is the address of
the supply in binary.
Acknowledge
SRQ
111x xxxx
None
Acknowledge SRQ. If retransmission
of SRQ is enabled, it will remain e
n-
abled for the next SRQ. X xxxx is the
address of the supply in binary.
Test if MD Mode
is Installed
Byte 1
1010 1010
Byte 2
xxxx xxxx
0 or 1
Returns a 0 if not installe
d or a 1 if
installed. A ‘$’ sign followed by a 2
bytes checksum and Carriage Return
is appended to the data. xxxx xxxx is
the address of the supply in binary.
Supply Initiated
Communications
SRQ
100x xxxx
N/A
SRQ from supply when in MD Mode.
X xxxx i
s the address of the supply in
binary.
Table 7
-
3. SINGLE BYTE COMMUNICATIONS
Table 7
-
4: Current programming range
Model
Minimum
(A)
Maximum
(A)
7.5
-
1000
0.0
1000.0
10
-
1000
0.0
1000.0
12.5
-
800
0.0
800.0
20
-
500
0.0
500.0
25
-
400
0.0
400.0
30
-
333
0.0
333.0
40
-
250
0.0
250.0
50
-
200
0.0
200.0
60
-
167
0.0
167.0
80
-
125
0.0
125.0
100
-
100
0.0
100.0
125
-
80
0.0
80.0
150
-
66
0.0
66.0
200
-
50
0.0
50.0
250
-
40
0.0
40.0
300
-
33
0.0
33.0
400
-
25
0.0
25.0
5
00
-
20
0.0
20.0
600
-
17
0.0
17.0
NOTE: