The power supply can accept values higher 5% than the table values, however it is not recommended to
program the power supply over the rated values.
or definition of the registers.
Reads the complete power supply status.
Returns ASCII characters representing the following data, separated by commas:
MV<actual (measured) voltage> PC<programmed (set) current>
PV<programmed (set) voltage> SR<status register, 2
MC<actual (measured) current> FR<fault register, 2
Example response: MV(45.201),PV(45), MC(4.3257), PC(10), SR(30), FR(00)
Set Fault Enable Register using 2
Reads Fault Enable Register. Returns 2
Reads Fault Event Register. Returns 2
digit hex. Clears bits of Fault Event Register.
s Status Conditional Register. Returns 2
Sets Status Enable Register using 2
Reads Status Enable Register. Returns 2
Reads Status Event register. Returns 2
digit hex. Clears bits of Status Event re