60
8303460000 Rev A IA672-04-01-Rev. I
12.4.9. Global Recall All Settings
This is the global version of the *RCL 0 command in section 11.7.4
Syntax: GLOBal:*RCL 0
Example: GLOB:*RCL 0
12.4.10. Error and Status Registers
The error and status registers described in sections 11.8.6 through 11.8.18 operate
somewhat differently in a multi-drop system.
The Status Byte and Standard Event registers are global. These do not change as
different power supplies are selected with INST:SEL
The Questionable Condition and Operational Condition registers are embedded in
the selected supply. These will change as different power supplies are selected with
INST:SEL