OUTPut:PON[:STATe]
AUTO - The power supply output will return to its previous value when the latching fault
condition is removed or to the stored value after AC recycle.
SAFE - The power supply output will remain Off after the fault condition is removed or after
AC recycle.
SCPI Command Syntax OUTPut:PON[:STATe] <bool>
GEN Command Syntax AST <bool>
Parameters 0|OFF 1|ON
*RST Value OFF
Examples OUTPut:PON 1
Query Syntax OUTPut:PON[:STATe]?
Returned Parameters 0|1
OUTPut:PROTection:CLEar
This command clears the latch that disables the output when an over voltage (OVP), under voltage
(UVP), or foldback (FOLD) fault condition is detected. All conditions that generate a fault must
be removed before the latch can be cleared. The output is then restored to the state before the
fault condition occurred.
SCPI Command Syntax OUTPut:PROTection:CLEar
GEN Command Syntax None
Parameters None
Examples OUTP:PROT:CLE
OUTPut:PROTection:FOLDback
Foldback mode is used to disable the output when a transition is made between the operation
modes. The power supply will turn off the output after a specified delay if the power supply makes
transition into CV mode or into CC mode. This feature is particularly useful for protecting current
or voltage sensitive loads.
SCPI Command Syntax OUTPut:PROT:FOLDback[:MODE] <CRD>
GEN Command Syntax FLD <CRD>
Parameters OFF|0, CC|1, CV|2 .
*RST Value OFF
Examples OUTPut:PROT:FOLDback[:MODE] CC
Query Syntax OUTPut:PROT:FOLDback[:MODE]?
Returned Parameters <CRD>