Normalized: a frame leaves the switch on this port with the VLAN
Tx octets: decimal value of sent octets on this port.
Rx octets: decimal value of received octets on this port.
Prevent Sleep Port: This option is available if the function “Prevent sleep” on “Control
panel” tab is deactivated.
This port is monitored: If there is incoming traffic on this port, the
MediaGateway doesn’t fall asleep.
This port is not monitored: The MediaGateway can fall asleep, even if there is
incoming traffic on this port.
Enable port:
port is active.
this port is not active: Incoming data is not forwarded and no outgoing traffic
possible.
Note: If there is a device connected on this port, link up can be shown by the
LED even if this port is not enabled.
BroadR-Reach® mode: For the MediaGateway there is no autonegotiation on
100BASE-T1 Ports available.
Slave: the connected device is a master and MediaGateway itself is a Slave
Master: the connected device is a Slave and MediaGateway itself is a Master
Output level: The “Output Level” is the amplitude level of the BroadR-Reach signal. You
can set Full level (FullOut = default) or half amplitude.
Note: Both devices of one 100BASE-T1 link must use the same level, otherwise the link
is not stable. FullOut is recommended.
Link quality: The “link quality” is an indicator about the signal integrity of the 100BASE-
T1 link on this port. 1 = Poor , 5 = Excellent. For more information about link quality and
its measurement, please contact Broadcom directly.
802.1AS mode:
For each port following values can be set:
DISABLED: Port will not take part of any 802.1AS traffic
BRIDGEX_MASTER: Port will take part of 802.1AS network as PTP-Bridge-
Master.
BRIDGEX_SLAVE: Only one Slave per BridgeX is allowed. MediaGateway will
take part of 802.1AS network as PTP-BridgeX-Slave
MASTER_802.1AS: Port will work as 802.1AS Master Clock. Only one
MasterClock per switch is possible.