BRAVO – Wireless Alarm Control Panel
26
To un-bypass (enable) a device:
- Enter in “Device enrolment” mode.
- The numbers of the bypassed devices are lighting
in yellow.
- Use the arrows to select the number of a bypassed
device, which you want to enable – blinking in
yellow.
- Press the “Bypass” button.
- The number of the device on the panel is blinking in
red.
- Press the button “Programming” several times
to exit the “Device enrolment” mode.
To bypass/ un-bypass a key fob:
- Enter in “Device enrolment” mode.
- Press the button “Programming” .
- Use arrow buttons to select a number of key fob,
which you want to bypass/ un-bypass.
- Press the “Bypass” button.
- Press the button “Programming” several times
to exit the “Device enrolment” mode.
To bypass/ un-bypass an outdoor sounder:
- Enter in “Device enrolment” mode.
- Press twice the button “Programming” .
- Press the “Bypass” button.
- Press the button “Programming” to exit the
“Device enrolment” mode.
Note: If a wired siren is connected to the panel
via BRAVO MOUT module it is shown as
enrolled device to position 16. The wired siren
can be bypassed in the same way as the
wireless sounder, as selecting position 16 and
pressing the “Bypass” button.
7.6. Deleting of Devices
The deleting is a complete removing the device from the
system configuration.
To delete a device:
- Enter in “Device enrolment” mode.
- Use arrow buttons to select a number of device,
which you want to delete.
- The number of the selected device on the panel is
blinking in red and detector’s LED(s) – in yellow.
- Press and hold the “Cancel” button until a
confirmation sound signal is heard.
- The number of the zone on the panel is blinking in
green.
- Press the “Programming” button several times
to exit the “Device enrolment” mode.
7.7. Resetting Detectors and Sounders
The resetting of a device is restoring of its default
factory settings. But the position to which the device has
been enrolled in the panel stays occupied. If the
occupied position is not deleted (see item 7.6), with the
next enrollment of the same device to the panel it will be
attached automatically to this position.
To reset a detector or outdoor sounder:
- Remove the cover of the device.
- With battery on, press the “RESET” or “RST” button
for 3-5 seconds until you see 3 green blinks from the
LED(s).
7.8. Resetting Key Fobs
- Press and hold at the same time + buttons
of the key fob until the button lights on in red.
- Release buttons + .
- Press the button while is lighting on in red (the
button will lighting on in arrond 5 seconds).
- Wait the button to blink three times in green –
the key fob is reseted.
ATTENTION: Before resetting of a MANAGER
key fob it is obligatory first to delete it or
bypass it from the panel!
The zone walk test is performed to all detectors in
the system including the bypassed ones.
Enter in zone walk test mode and start system
testing from the near to control panel devices.
Press a random button of the key fob every time
after a successful test to prolong the time of the
test.
If you are not familiar with the system configuration
you can check the detector number (zone number),
as enter in “Device enrolment” mode – the number
of a selected device is blinking in red on the panel,
and the device LED(s) – in yellow.
It is recommended to remove the batteries of all
bypassed, deleted and reset devices if you plan not
to use them for a long time.