BRAVO – Wireless Alarm Control Panel
41
Ajax WEB
Specialized user web interface for programming,
monitoring and management of intruder alarm control
panels produced by Teletek Electronics JSC. The
application requires mounted GPRS or LAN
communication modules to the panel’s configuration.
Arming
This is an action for preparing the system for full or
partial protection of the premises (Full ARM or Stay
ARM). In Full ARM mode, in case of violation in instant
type zone the sirens will be activated immediately and
message for burglary alarm will be transmitted to User
or monitoring station (via GPRS or PSTN channel if
there is mounted communication module in the panel).
Bypass
This is a temporary excluding (disabling) a device or
zone from the system configuration. The panel does not
follow the status of a bypassed device or zone.
Communication module
This is a specialized device for transmitting messages
for alarm or trouble events to user or monitoring station
via GPRS, PSTN or other communication channel.
Control panel
This is a control device gathering information for the
current system status from all enrolled to it devices in
the system configuration. The control panel informs the
user for all alarm and trouble events in the system with
sound and LED signalization.
Detector
This is a device sending signals to the control panel in
case of detecting some specific activity in the protected
zone. For example, BRAVO PIR detects movement;
BRAVO FL detects water presence, and so on.
Device Group
The devices with same type are organized into groups.
For example, in BRAVO panel, the devices PIR, MC,
FD and FL form the group of Detectors; RC and panic
buttons form the group of key fobs, etc.
Disarming
This is an action for stopping the full or partial protection
of the premises. In disarmed state the panel will indicate
only with LED indication the activated zones without
sound signalization.
Double Action Mode
This is a specialized operation mode in BRAVO PIR for
minimization of the false alarms in the system. In double
action mode the detector will generate an alarm event
only if there are two consecutive activations of the zone
in time period of 60 sec.
Enrollment of device
The enrollment is a process for adding devices to
system configuration.
Key fob transmitter
This is a control device for remotely arming and
disarming the system.
MobileTTE
Specialized smart phone application for management
and monitoring of intruder alarm control panels
produced by Teletek Electronics JSC. The application
requires mounted GPRS communication module to the
panel’s configuration.
ProsTE
Specialized software for programming of intruder and
fire alarm control panels produced by Teletek
Electronics JSC. The software is free of charge and can
be downloaded from the official web page of the
manufacturer.
Reset of device
This is a process for restoration of the factory settings of
a device.
Security system
This is a set of devices enrolled to a supervising control
panel, all located in the premises of the protected area.
Signal Strength
This is the quality of the communication link between
the control panel and devices in the system.
Siren
This is a sound signalization device which is activated in
case of alarm event in the system during Full ARM or
Stay ARM mode.
Tamper
This is a specialized button (or switch) for self-protection
of the device box. In normal state the tamper-button
stays pressed from the cover of the device, and in case
of opening will generate sound signalization for
technical trouble (see also item 4.4).
Type of zone
It is defined according the requirements for reaction of
the system in case of alarm or other signal from the
respective device. All zone types are described in item
4.2.
Zone
This is a separated part of the total protected area,
which is monitored by a detector enrolled to the system
configuration.
Zone (Device) Activation
This means that a device, which monitors the status of a
zone is detected some specific activity in the protected
zone (the device is activated). For example: BRAVO
PIR is activated from a movement; BRAVO MC
magnetic contact is open – the two parts are separated
on distance 30mm or more; BRAVO FD fire detector is
activated from a smoke and raising heat, and so on.
Note: Other terminology for zone (device) activation is
zone opening.
Zone (Device) Restore
This means that a device, which monitors the status of a
zone has come back to normal operation mode.
See also the definition for Zone (Device) Activation.