5.1.5 SMS Event Time Zones
FMB010 works with synchronized GPS time which is UTC+0, with this option customer can
configure his time zone and get SMS with correct time.
Note: Please do not set Data Send Number to some cell phone number,
because it will not understand binary SMS. When sending a binary SMS to a
phone number, which is a server phone number, the server can interpret and
understand binary code, so the data can be read and you can view it on the
server.
SMS login and password and authorized number list are used to protect
FMB010 module from unauthorized access. Module accepts messages only
from a list of authorized numbers and with proper module login and password.
Numbers must be without “+” or “00” prefix. If no authorized numbers are
entered, module accepts messages from all numbers.
5.1.6 SMS events
SMS events functionality allows FMB010 to send a configured SMS when an event is
triggered. This event can be triggered by ever I/O element.
Then any of the I/O elements is triggered, FMB010 sends a configured SMS message to a
defined phone number. If SMS events is activated, but there are no numbers defined in SMS
events PreDefined Numbers list (figure 20), then the device will not send any messages.