71
0
2592000
-
Min Distance (ID=10151)
Min Angle (ID=10152)
U32
6.6.6.2 Min Distance (ID=10251)
This parameter indicates distance in meters in order to acquire new record. Record is
stored when the distance between previous records is greater than parameter’s value. If value is
0 it means no records by min distance will be saved.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
65535
-
Min
Perio
d
(ID=1
0150
)
Min Angle (ID=10152)
U32
6.6.6.3 Min Angle (ID=10252)
This parameter indicates angle in degrees in order to acquire new record. If angle
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. This parameter is operational, when speed is higher than 10km/h. If value
is 0 it means no records by min angle will be saved.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
180
-
Min Period (ID=10150)
U16
6.6.6.4 Min Speed (ID=10253)
This parameter indicates speed difference in order to acquire new record. If speed
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. If value is 0 it means no records by min distance will be saved.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
255
10
Min Period (ID=10150)
Min
Dista
nce
(ID=1
0151
)
Min Angle (ID=10152)
U16