74
6.7.11 Overspeeding output control (ID=11103)
Enables (1) or disables (0) overspeeding output control
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
0
Float
6.7.12 Overspeeding Digital output on duration (ID=11101)
Output ON duration in mili-seconds
Minimum
value
Maximum
value
Default value
Goes with (depends on)
parameters
Value
type
0
21474836
47
200
U8
6.7.13 Overspeeding Digital output off duration (ID=11102)
Output OFF duration in mili-seconds
Minimum
value
Maximum
value
Default value
Goes with (depends on)
parameters
Value
type
0
21474836
47
200
U8
6.7.14 Excessive idling priority (ID=11200)
Defines priority of Excessive idling scenario:
0 – disabled, 1 – low, 2 – high, 3 – panic
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
3
-
U8
6.7.15 Eventual records (ID=11203)
Disables (0) or enables (1) eventual records with idling value
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
U16
6.7.16 Excessive idling minimum stop duration (ID=11205)
Defines minimum time in seconds of vehicle idling before scenario enables.
Minimum
value
Maximum
value
Default value
Goes with (depends on)
parameters
Value
type
0
255
5
Float

Table of Contents