67
6.6.2.2 Min Distance (ID=10051)
This parameter indicates distance in meters in order to acquire new record. Record is
stored when the distance between previous records is greater than parameters value. If value is
0 it means no records by min distance will be saved.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
65535
-
Min Period (ID=10050)
Min Angle (ID=10052)
U32
6.6.2.3 Min Angle (ID=10052)
This parameter indicates angle in degrees in order to acquire new record. If angle
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. This parameter is operational, when speed is higher than 10km/h. If value
is 0 it means no records by min angle will be saved.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
180
-
Min Period (ID=10050)
Min Distance (ID=10051)
U16
6.6.2.4 Min Speed delta (ID=10053)
This parameter indicates speed difference in order to acquire new record. If speed
difference between last recorded coordinate and current position is greater than defined value,
new record is stored. If value is 0 it means no records by min distance will be saved.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
255
10
Min Period (ID=10050)
Min Distance (ID=10051)
Min Angle (ID=10052)
U16
6.6.2.5 Min Saved Records (ID=10054)
This parameter defines minimum number of records in one data packet that can be sent to
server. It has higher priority than Data Send Period (ID=10055).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1
255
1
Min Period (ID=10050)
Min Distance (ID=10051)
Min Angle (ID=10052)
U8
6.6.2.6 Send Period (ID=10055)
This parameter indicates frequency (time interval in seconds) of sending data to server.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2592000
-
U32

Table of Contents