6.7.23 Jamming Output Control (ID=11304)
Defines rather jamming will control digital output or not. 0 Disable, 1 Enable.
Minimum
value
Maximum
value
Default value
Goes with (depends on)
parameters
Value
type
0
1
0
U8
6.7.24 Jamming DOUT on duration [ms] (ID=11301)
Sets time period, that Dout will be on.
Minimum
value
Maximum
value
Default value
Goes with (depends on)
parameters
Value
type
0
21474836
47
200
U8
6.7.25 Jamming DOUT off duration [ms] (ID=11302)
Sets time period, that Dout will be off.
Minimum
value
Maximum
value
Default value
Goes with (depends on)
parameters
Value
type
0
21474836
47
200
U8
6.7.26 DOUT control via call (ID=12000)
Disables or enables dout control via call. 0 Disable, 1 Enable.
Minimum
value
Maximum
value
Default value
Goes with (depends on)
parameters
Value
type
0
1
0
U8
6.7.27 DOUT deactivation settings (ID=12001)
Enables or disables dout deactivation by Din1. 0 Disable, 1 Enable.
Minimum
value
Maximum
value
Default value
Goes with (depends on)
parameters
Value
type
0
1
0
U8
6.7.28 DOUT duration timeout [s] (ID=12002)
Defines the time that dout will be activated for.
Minimum
value
Maximum
value
Default value
Goes with (depends on)
parameters
Value
type
0
21474836
47
5
U8