6.6.6.5 Min Saved Records (ID=10254)
This parameter defines minimum number of records in one data packet that can be sent to
server. It has higher priority than Data Send Period (ID=10105).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1
255
1
U8
6.6.6.6 Send Period (ID=10255)
This parameter indicates frequency (time interval in seconds) of sending data to server.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2592000
-
Min Saved Records (ID=10104)
U32
6.7 Features Parameters
6.7.1 Green driving priority (ID=11000)
Defines priority of green driving scenario:
0 disabled, 1 low, 2 high, 3 panic
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
3
-
U8
6.7.2 Max Acceleration Force (ID=11004)
It is max allowed acceleration force which can be reached while accelerating without
triggering harsh acceleration event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
0.25
Float
6.7.3 Max Braking Force (ID=11005)
It is max allowed braking force which can be reached while braking without triggering
harsh braking event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
0.35
Float
6.7.4 Max Cornering (ID=11006)
It is max allowed cornering angle which can be reached while cornering without triggering
harsh cornering event.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
U16