EasyManua.ls Logo

Teltonika FMB010 - I;O parameters; I;O#1 averaging length (ID=50005); I\O elements parameters and types.

Teltonika FMB010
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
84
6.12.6 I/O#1 averaging length (ID=50005)
Parameter defines I/O property sample length to average. If no averaging needed default
value is 1.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on) parameters
Value
type
0
2147483647
1
I/O#1 priority (ID=50000)
I/O#1 logic operand (ID=50001)
I/O#1 High level (ID=50002)
I/O#1 Low level (ID=50003)
I/O#1 Event only (ID=50004)
I/O#1 averaging length (ID=50005)
S32
Other I/O property elements can be configured in same logic. All I/O element parameters
are listed in the next table.
6.13 I\O elements parameters and types.
Parameter
ID
Parameter
Type
Default value
Value range
Parameter name
Min
Max
50000
Uint8
1
0
3
Ignition Priority
50001
Uint8
5
0
6
Ignition Operand
50002
Uint8
0
0
1
Ignition High level
50003
Uint8
0
0
1
Ignition Low level
50004
Uint8
0
0
1
Ignition Event only
50005
Uint16
10
0
65535
Ignition Average
7000
Uint8
0
0
10
Send SMS
8000
String
0
0
160
SMS Text
50010
Uint8
1
0
3
Movement Priority
50011
Uint8
5
0
6
Movement Operand
50012
Uint8
0
0
1
Movement High level
50013
Uint8
0
0
1
Movement Low level
50014
Uint8
0
0
1
Movement Event only
50015
Uint16
1
0
65535
Movement Average
7001
Uint8
0
0
10
Send SMS
8001
String
0
0
160
SMS Text
50020
Uint8
1
0
3
Data Mode Priority
50021
Uint8
5
0
6
Data Mode Operand
50022
Uint8
0
0
5
Data Mode Hight level
50023
Uint8
0
0
5
Data Mode Low level
50024
Uint8
0
0
1
Data Mode Event only
7002
Uint8
0
0
10
Send SMS
8002
String
0
0
160
SMS Text
50030
Uint8
1
0
3
GSM Signal Priority
50031
Uint8
5
0
6
GSM Signal Operand

Table of Contents