• Theannual/comprehensiveandmonthlyinspectionsmustbedocumentedaccordingto1926.1412(f)(7)
and1916.1412(e)(3),respectively.
• Ropelubricantsofthetypethathinderinspectionmustnotbeused.
• Alldocumentsproducedunderthissectionmustbeavailable,duringtheapplicabledocumentretention
period,toallpersonswhoconductinspectionsunderthissection.
Shift Inspection
Shiftinspectionsarevisualinspectionsthatacompetentpersonmustbeginpriortoeachshiftduring
whichtheequipmentisused.Shiftinspectionsdonotrequireuntwisting(opening)ofwireropesor
boomingdown.Theinspectionmustconsistofobservationofwireropes(runningandstanding)thatare
likelytobeinuseduringtheshiftforapparentdeciencies,includingthefollowing:
Subpart CC – Cranes and Derricks in
Construction: Wire Rope – Inspection
This fact sheet describes the inspection requirements of subpart CC – Cranes and
Derricks in Construction, as specified in 29 CFR 1926.1413. These provisions are
effective November 8, 2010. This document is intended to assist wire rope inspectors
and supervisors.
Inspection Trigger Inspection Details Performed by Documentation
Eachshift
Seelistbelow,visual
inspectionmustbegin
priortoeachshiftin
whichtheequipment
isused.
CompetentPerson Notrequired
Monthly Seedetailsbelow. CompetentPerson
Required.Mustbesignedbytheperson
whoconductedtheinspectionand
retainedforaminimumof3months.
Annual Seedetailsbelow. QualiedPerson
Required.Mustbesignedbytheperson
whoconductedtheinspectionand
retainedforaminimumof12months.
Apparent Deficiencies – Category I Removal from Service Criteria
• Signicantdistortionofthewireropestructuresuch
askinking,crushing,unstranding,birdcaging,signsof
corefailure,orsteelcoreprotrusionbetweentheouter
strands.
• Signicantcorrosion.
• Electricarcdamage(fromasourceotherthanpower
lines)orheatdamage.
• Improperlyappliedendconnections.
• Signicantlycorroded,cracked,bent,orwornend
connections(suchasfromsevereservice).
IfaCategoryIdeciencyisidentied,thecompetent
personmustimmediatelydeterminewhetherit
constitutesasafetyhazard.Ifthedeciencyis
determinedtobeasafetyhazard,alloperations
involvinguseofthewireropeinquestionmustbe
prohibiteduntil:
• Thewireropeisreplaced.(See1926.1417),or
• Ifthedeciencyislocalized,theproblemiscorrected
byseveringthewireropeintwo;theundamaged
portionmaycontinuetobeused.Joininglengths
ofwireropebysplicingisprohibited.Ifaropeis
shortenedunderthisparagraph,theemployermust
ensurethatthedrumwillstillhavetwowrapsofwire
whentheloadand/orboomisinitslowestposition.