When the crane is to be rigged, it is often
necessary to put the boom in a position that
could cause function kick-out. Using the bypass
is necessary in this situation.
Press and release and then press and hold
the CANCEL ALARM push button (item 23)
for approximately 5 seconds to reset the
relay. At this time a second beep is heard
confirming the bypass. When the condition
that caused the alarm is no longer present,
the function disconnect relay will reset to the
normal condition. Should a different alarm
condition occur while the relay is over-
ridden, the new alarm condition will cause
the controls to disconnect again
.
WHEN THE FUNCTION DISCONNECT RELAY
IS RESET BY MEANS OF THE CANCEL
ALARM PUSH BUTTON, THERE IS NO
LONGER PROTECTION AGAINST THE
CONDITION THAT CAUSED THE FUNCTION
KICK-OUT.
TEST
6
23,500
i2,300
44.8
62.7
26.4
23
WARNING