GREER COMPANY 1918 EAST GLENWOOD PLACE, SANTA ANA, CA 92705 PN W450250 Rev A 06/01/00
TEREX RCI 510 RATED CAPACITY INDICATOR OPERATOR'S MANUAL TEL:(714) 259-9702 FAX:(714) 259-7626
22 of 35
The
cancel alarm push button
(item 23) is
used to silence the audible alarm.
Pressing this
button once will cancel an audible alarm that
has occurred as a result of an:
Overload
A2B Alarm
Operator Settable Alarm
The audible alarm remains canceled until the
condition that caused the alarm has been
removed. See page 23.
EXAMPLES:
AFTER CANCELING AN AUDIBLE ALARM:
If the audible alarm sounded because of an
overload condition, the alarm will remain
canceled until the condition is corrected.
If
another
alarm condition occurs
that
normally causes an alarm to sound (such
as A2B)
or if a previous condition
(such as overload)
is removed and then
recurs, the new alarm condition will cause
the audible alarm to sound again.
The CANCEL ALARM push button is also used
to reset the function kick-out relay when it is
necessary to bypass the function disconnects.
Examples of when it may be necessary to
override a function disconnect condition are:
If the boom hoist cylinder is fully extended, the
pressure in it will rise. This will be seen by the
system as an overload and will not allow the
operator to boom down. Using the bypass is
necessary in this situation to move away from
the fully extended boom hoist cylinder position.