EasyManua.ls Logo

Textron Cessna 182S - Page 107

Textron Cessna 182S
743 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CESSNA
AIRCRAFT
COMPANY
MODEL
182/T182
WIRING
DIAGRAM
MANUAL
Table
202.
Color
Codes
for
Single
Conductor,
Unshielded
Wires
0=BLACK
1=BROWN
2=RED
5=GREEN
6=BLUE
7=VIOLET
3=ORANGE
8=GRAY
4=YELLOW
9=WHITE
wire has
a
wire
specification
of
M81044/12-22-9.
EXAMPLE:
3S183-SP227(20),
single
conductor
high
temperature
wire
has
a
wire
specification
of
M22759/3-20-9.
EXAMPLE:
GND17-ESG1(00),
single
conductor
starter
generator
has
a
wire
specification
of
M22759/41-00-9.
(5)
For
twisted
unshielded
wire
uses
part
number
M27500
-
(GAGE)
ML
*
UOO.
Substitute
*
with
the
number
of
conductors.
EXAMPLE:
Pair
of
wires,
EJF28-MPF143(20)
WHITE
and
FJF28-KPF143(20)
BLACK
(shown
as
pair
on
diagram)
has
a
wire
specification
of
M27500-20ML2U00.
(6) For
Shielded
single
and
multiconductor
wire
use Part
number
M27500
-
(GAGE)
ML
*
T08.
Substitute
*
with
the number
of
conductors.
EXAMPLE:
9PT52-9PT54(22)
(shown
as
shielded
on
the
diagram)
has
a
wire
specification
of
M27500-22ML1T08.
D.
Single
Conductor
Shielded,
Jacketed
and
Multiconductor
Wires.
(1)
Refer
to Figure
202
for
an
explanation
of
MIL-C-27500
part numbers.
E.
Special
wires
are
used
in
the
control
wheels.
(1)
Order
S3333-1
Multiconductor
Cable
for
the
left
control
wheel.
(2)
Order
S3333-2
Multiconductor
Cable
for
the
left
control
wheel
with
Electric
Trim.
(3)
Order
S3333-3
Multiconductor
Cable
for
the
right
control
wheel.
4.
Wire
Identification
A.
Refer
to
Introduction
for details
of
wire numbering.
B.
Each
wire
shall
be
identified
with
legible
characters
at
intervals
not
exceeding
15
inches
for
the length
of
the wire.
The
wire
should
also
be
marked
approximately
3
inches
from
each
break
or
each
terminal
except
that
this
distance
can
be
increased
to install
ties,
clamps,
connectors,
supporting
devices
or
terminals.
C.
No
identification
marks
or
numbers
are
required
on
external
wires
that
are
part
of
vendor
furnished
equipment.
D.
Wires
or
cables
less
than
3
inches
in
length
need
not
be
identified.
E.
Wire
identification
can
be
marked
on
the
wire
as
follows:
(1)
Hot
embossing
of
single
wire.
(2)
Hot
embossing
of
pressure
sensitive
tape.
(3)
The
marking
of
vinyl
sleeves.
(4)
The
marking
of
printing
foils.
F.
Coaxial
cables
may
be
identified
by
applying
the
identification
code
directly
to
shrink
tubing
and
installing
within
3
inches
of
termination.
20-10-01
Page
202
©
Cessna
Aircraft
Company
Mar
1/2004

Table of Contents

Related product manuals