CESSNA AIRCRAFT
COMPANY
MODEL
182/T182
WIRING
DIAGRAM
MANUAL
CAUTION:
MAKE
SURE
THAT
FLUID
DOES
NOT
CONTACT
WIRES,
AND
REMOVE
ANY
FLUID
FROM
THE WIRES,
THE
HARDWARE
THAT
HOLDS THEM,
OR
AVIONICS AND
ELECTRICAL
EQUIPMENT.
COLLECT
AND
DISCARD
ANY
FLUID
SPILLED
WITH CLOTHS,
PLASTIC
SHEETS,
AND
CONTAINERS.
FLUID CONTAMINATION
CAN
CAUSE
WIRE
INSULATOR
DETERIORATION
AND
SHORT
CIRCUITS.
(4)
Wires shall
not
be
routed
closer
than
3
inches
to
components
producing
heat
in
excess
of
140°F.
Wires
required
to
connect
with
heat
producing
components
shall
be
routed
directly
away
from
the
component
and
maintain
the
3
inch
clearance
thereafter.
Wiring operating
in
elevated
temperatures
shall
be
wrapped
with
tape
or contained
in
conduits.
(5)
Wires and
cables
shall
be
positioned or
protected
to
avoid
contact
with rough
or
irregular surfaces
and
sharp
edges.
(a)
All
wiring
shall
be
protected
from
chafing
by
the
use
of
grommets,
protective
sleeves,
by
proper
support
and
correct
routing.
(b)
All
screws
or
metal
edges that
are
within 0.20
inch
of
a
wire
or
cable
shall
be
coated
with
Glyptal,
protected
by
nylon
caterpillar-type
grommets or
other
protection.
(c)
Wiring
shall
be
routed
to
avoid
contact
with
moving
parts.
(d)
Wiring
around
sharp
edges should
be
avoided
at
all
times.
CAUTION:
USE
A CLOTH
TO
COVER
ANY
WIRES,
AVIONICS
OR
ELECTRICAL
EQUIPMENT
THAT
IS
IN
A
LOCATION
WHERE
METAL
CHIPS
OR SHAVINGS
CAN
FALL.
BE
SURE
TO REMOVE
ANY
METAL
CHIPS OR
SHAVINGS
FROM
WIRES,
AVIONICS
AND
ELECTRICAL
EQUIPMENT.
CONTAMINATION FROM
METAL
SHAVINGS
CAN
CAUSE
WIRE
INSULATOR
DETERIORATION AND
SHORT
CIRCUITS
(e)
Wiring
shall
be
routed so they
will
not be
crushed
or
pinched
during
installation.
Lightly
coat wire
with
petroleum
jelly
or water
before
pulling
through
pressure
feed-thru.
Leave
enough
slack
in
wiring
to
accomplish
the
following:
(a)
Permit
staking
of
terminals.
(b)
Ease
of
maintenance.
(c)
Permit
free
movement
of
shock-mounted
equipment.
(d)
Prevent
mechanical
strain
on
wiring
and
wiring
supports.
(e)
Provide
adequate
drip
and
service
loops.
CAUTION:
DRIP
LOOPS
MUST
BE
ARRANGED
SO
THAT
DRIP
FROM
LOOP
DOES
NOT
FALL
ON EQUIPMENT
WHICH
MIGHT
BE
ADVERSELY
AFFECTED.
ON
MOISTURE
RESISTANT
CONNECTORS,
DRIP
LOOPS
MAY
BE
OMITTED
WHERE
SPACE
IS
LIMITED.
COAXIAL
CABLE
ASSEMBLIES
IDENTIFIED
AS
IMPEDANCE
MATCHING
UNITS
MUST
BE
A
SPECIFIED
LENGTH.
DO NOT
SHORTEN
CABLE
TO
REMOVE EXCESS
SLACK.
(8)
The
securing
of
wire
groups,
bundles,
sleeves,
adapter
clamps
and
tape
shall
be
accomplished
with
a
clove hitch
knot
secured
with
a square
knot.
Refer to
Figure
203.
(a)
MIL-T-713 twine
and
Sta-straps shall
be
limited
in
use
to operational temperatures
of
less
than
200°F.
(b)
The
free
ends
of
the
MIL-T-713
twine shall
be
a
minimum
of
3/8
inch
long.
(c) Wire
groups
or
bundles shall
be
tied
at
intervals
not
to exceed
12
inches.
20-10-01
Page
206
©
Cessna
Aircraft
Company
Mar
1/2004
(6)
(7)