Table
213.
Standard
Flag
Terminals
(continued)
WIRE
SIZE
(AWG)
STUD
SIZE
PART NUMBER
4
10
MS25189-12
4
1/4
MS25189-13
4
5/16
MS25189-14
4
3/8
MS25189-15
4
1/2
MS25189-16
2 10
MS25189-17
2
1/4
MS25189-18
2
5/16
MS25189-19
2
3/8
MS25189-20
2
7/16
MS25189-21
2
1/2
MS25189-22
NOTE:
The
flag
terminals
listed
in
Table
214
are
for use
in
fuel
cells.
Table
214.
Fuel
Quantity
Probe
Flag
Terminals
NAME PART
MANUFACTURER
NUMBER
#6
Terminal
36195
AMP
Inc.
V00779
#8
Terminal
34117
AMP
Inc.
V00779
#10
Terminal
34118
AMP
Inc.
V00779
Crimper
WT111
M
Thomas
and
Betts
#6
Terminal
AB51
Thomas
and
Betts
#8
Terminal
AB52
Thomas
and
Betts
#10
Terminal
AB53
Thomas
and
Betts
12.
CHECKING
TERMINALS
AND
SPLICES
A.
Electrical
Resistance.
(1)
Properly
installed terminals
and
splices
shall
offer
no
more
resistance
across
the
terminal
than
an
equivalent
length
of
wire
of
the same
gage
to
which
the
terminal
is
attached.
B.
Tension
Load
Testing.
(1)
To
test
crimping
tools
used
for installing
terminals
and splices,
a
sample
wire and
terminal
or
splice
should
withstand
the
tension
loads
in
Table
215.