CESSNA
AIRCRAFT
COMPANY
MODEL
182/T182
WIRING
DIAGRAM
MANUAL
FIG
REF
DES
PART
NUMBER
01
ACU AC2100
ACU AC2101
CN001
F1
F1
F2
F2
F4
GN002
GN008
J1
J2
J3
J4
JC001
S1915-2
F53-0002
P52-0006
F53-0002
P52-0006
F51-0003
AGC5
5/16-18NC
39-0050588-00
39-0403023-04
770585-1
MS3506-1
S2349-5
S2099-3
S2099-4
J1006
770585-1
170365-3
S3556-26
K1
X61-0007
K2
X61-0012
K3
X61-0007
K4
X61-0007
MN001
9910591-11
P4
PB017
S2800-275
PB018
S2800-274
PC001
S2350-10
S2353-4
S2353-5
U1
CS3100
UI005
CSEWCA-01
1234567
NOMENCLATURE
EFFECTIVITY
FROM
TO
ALTERNATOR
SYSTEM
18280001
THRU
18280944
.
CONTROL
UNIT ALTERNATOR
.........................
V65702
80001
.
CONTROL
UNIT
ALTERNATOR
........................
V65702
80390
8232
.
CAPACITOR
ALTERNATOR
(ZONE
120)
...................
.FUSE
(ZONE
120)
.................................
V65702 80676
.FUSE
..........................................
V65702
80001
FUSE
(ZONE
120)
.................................
V65702 80676
.
FUSE
.........................................
.
V65702
80001
FUSE
CLOCK
(ZONE
120)
.................
V..........V3RCD2
FUSE
ALTERNATE
FOR
F51-0003 V65702
GROUND
STUD
..................................
V65702
.
GROUND
(ZONE
211)
...............................
CONNECTOR
STROBE
DISCONNECT (ZONE
121)
...........
V10402
.
CONTACT
V10402
CONNECTOR
POWER
SUPPLY DISCONNECT
(ZONE
121)
.....
V00779
.
CONNECTOR
(ZONE
121)
............................
CONNECTOR
(ZONE
121)
............................
CONNECTOR
CIRCUIT
BREAKER
PANEL
DISCONNECT
(ZONE
224)
............................................
..
CONTACT
.
CONTACT
CONNECTOR (ZONE
225)
............................
V00779
.
CONTACT
V00779
80001
.
CONTACT
80945
.
RELAY
ALTERNATOR
(ZONE
121)
.......................
V65702
.
RELAY
START
(ZONE
121)
............................
V65702
RELAY
EXTERNAL
POWER
(ZONE
121)
.................
V65702
.
RELAY
BATTERY
(ZONE
121)
..........................
V65702
ALTERNATOR
(ZONE
120)
............................
80001
CONNECTOR
POWER JUNCTION
BOX
(ZONE
121)...........
.
CONNECTOR POWER
JUNCTION
BOX
(ZONE
121)...........
80001
CONNECTOR POWER
JUNCTION
BOX
(ZONE
121)...........
.
CONNECTOR
CIRCUIT
BREAKER
PANEL
DISCONNECT
(ZONE
224)
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . .
.
CONTACT
.
CONTACT
SENSOR
CURRENT
(ZONE
121)
........................
V65702
80001
8001
ANNUNCIATOR
PANEL
(ZONE
225)
......................
VOGZF3
-
ITEM
NOT
ILLUSTRATED
©
CESSNA
AIRCRAFT
COMPANY
80389
&
ON
&
ON
81197
80675
81197
80675
80944
&
ON
81197
80944
81475
8336
UNITS
PER
ASSY
01
01
01
01
01
01
01
01
01
01
RF
01
01
01
01
RF
01
AR
AR
01
AR
AR
01
01
01
01
01
RF
01
01
01
AR
AR
01
01
Figure
01
Page
1
24-20-01
Feb
13/2006