EasyManua.ls Logo

Textron Cessna 182S - Page 437

Textron Cessna 182S
743 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CESSNA
AIRCRAFT
COMPANY
MODEL
182/T182
WIRING
DIAGRAM
MANUAL
FIG
REF
DES
PART
NUMBER
01
EI021
351-38933-001
GI001
S3270-2
-
S2099-13
S2099-3
S2099-4
GN008
HI011
CM3589-20
HI022 S1360-5L
JC001
S2349-5
S2099-3
S2099-4
JC010
S1641-9
S1636-1
S1636-2
JC018
S1638-6
S1636-1
S1636-2
JI022
176284-1
175153-2
PC001
S2350-10
S2353-4
S2353-5
PC010 S1640-9
S1635-1
S1635-2
PC013
S2349-3
S2099-3
S2099-4
S2351-3
S3373-2
PC018 S1638-4
S1635-1
PI022
S2035-1
-S1635-1
TN001
B40245-53
TN002
B40245-53
TN003
B40245-53
UC001
C614002-0102
XN001
C40660
MS25171-1S
NOMENCLATURE
EFFECTIVITY
FROM TO
1234567
PROPELLER
DEICE
18208001 THRU
18208224
.
ANNUNCIATOR
PROPELLER
DEICE
.....................
V96182
.
GROUND
BLOCK
(ZONE
211)
..........................
.
CONTACT
.
CONTACT
.
CONTACT
GROUND (ZONE
211)
...............................
.
CIRCUIT
BREAKER
(ZONE 224)
........................
8001
8231
.
CIRCUIT
BREAKER
(ZONE
224)
........................
.
CONNECTOR
CIRCUIT
BREAKER
PANEL
DISCONNECT (ZONE
224)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . .
..
CONTACT
.
CONTACT
.
CONNECTOR CIRCUIT
BREAKER
PANEL
DISCONNECT (ZONE
22
4)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
CONTACT
.
CONTACT
CONNECTOR
(ZONE 225)
............................
.
CONTACT
.
CONTACT
CONNECTOR
DEICE DISC
(ZONE 224)
...................
V00779
.
CONTACT
CONNECTOR CIRCUIT
BREAKER
PANEL
DISCONNECT
(ZONE
224)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
..
CONTACT
.
CONTACT
.
CONNECTOR CIRCUIT
BREAKER
PANEL
DISCONNECT
(ZONE
224)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . .
.
CONTACT
.
CONTACT
.
CONNECTOR
DE-ICE
TIMER/MONITOR (ZONE
211)
..........
.
CONTACT
.
CONTACT
.
CLAMP
.
CONTACT
CONNECTOR
SWITCH
DEICE
DISCONNECT (ZONE
225)
......
8001
&
On
.
CONTACT
CONNECTOR
DEICE
DISCONNECT
(ZONE
224)
.............
.
CONTACT
HEATER
PROPELLER (ZONE
110)
.......................
HEATER
PROPELLER (ZONE
110)
.......................
HEATER
PROPELLER (ZONE
110)
.......................
BATTERY
(ZONE
211)
............................... 81198
&On
.
BRUSH BLOCK ASSEMBLY
PROPELLOR
DEICE
(ZONE
120)
. . .
.
TERMINAL
8001
&
On
-
ITEM
NOT
ILLUSTRATED
©CESSNA
AIRCRAFT
COMPANY
UNITS
PER
ASSY
01
R
01
R
02
R
AR
R
AR
R
RFR
01
R
01
R
01
R
AR
R
AR
R
01
R
AR
R
AR
R
01
R
AR
R
AR
R
01
R
AR
R
01
R
AR
R
AR
R
01
R
AR
R
AR
R
01
R
AR
R
AR
R
01
R
AR
R
01
R
AR
R
01
R
AR
R
01
R
01
R
01
R
01
R
01
R
AR
R
30-60-01
Figure
01
Page
1
Mar 1/2004

Table of Contents

Related product manuals