SECTION 3 CESSNA
EMERGENCY PROCEDURES MODEL 208B 867 SHP
GARMIN G1000
U.S.
FAA APPROVED
FUEL SYSTEM (Continued)
RED FUEL SELECT OFF ANNUNCIATOR COMES ON
PRIOR TO ENGINE START AND AURAL WARNING
HORNS NOT SOUNDING
1. START CONT Circuit Breaker. . . . . . . . . . . . . CLOSE (push in)
(top row, third breaker from forward end)
2. FUEL SEL WARN Circuit Breaker. . . . . . . . . . CLOSE (push in)
(second row, first breaker from forward end)
When the START CONT or FUEL SEL WARN Circuit
Breakers are in the open position, the FUEL SELECT OFF
annunciator will come on and aural warning horns will not
sound.
Do not close (reset) circuit breakers more than once
and only after a 2 minute cool off period.
IF RED FUEL SELECT OFF ANNUNCIATOR REMAINS ON
3. Determine cause and repair before next flight.
IF RED FUEL SELECT OFF ANNUNCIATOR GOES OFF
3. Continue with engine start procedure.
208BPHCUS-00