CESSNA SECTION 4
MODEL 208B 867 SHP NORMAL PROCEDURES
GARMIN G1000
U.S.
FAA APPROVED
CRUISE
1. Ice Protection . . . . . . . . . . . . . . . . . . . . . . . . . . AS REQUIRED
a. PITOT/STATIC HEAT Switch . . . . . . . . . . . . . . . . . . . . . ON
(when OAT is below 5°C (41°F) and in visible moisture)
b. STALL HEAT Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . ON
(when OAT is below 5°C (41°F) and in visible moisture)
2. INERTIAL SEPARATOR. . . . . . . . . . . . . . . . . . . . . . . . . . . SET
(position INERTIAL SEPARATOR to NORMAL or BYPASS as
conditions warrant)
3. PROP RPM Lever. . . . . . . . . . . . . . . . . . . . . 1600 to 1900 RPM
4. POWER Lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SET
(observe Maximum Cruise Torque, ITT and N
g
limits)
Refer to Section 5, Performance, Figure 5-19 or Figure 5-36,
Cruise Performance and/or Figure 5-20 or Figure 5-37, Cruise
Maximum Torque for approved engine power settings.
5. Fuel Balance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CHECK
(maximum fuel imbalance 200 pounds)
For every 10°C (18°F) below -30°C (-22°F) ambient
temperature, reduce maximum allowable N
g
by 2.2%.
The Garmin G1000 incorporates a temperature
compensating N
g
redline.
208BPHCUS-00 4-37