189SDK (Software development Kit)
© 2010 Thorlabs
7.3.46
is_GetUsedBandwidth
USB 2.0
USB 2.0
Syntax
INT is_GetUsedBandwidth (HIDS hCam)
Description
is_GetUsedBandwidth() returns the bus bandwidth (in Mbit/s) currently used by all initialised or
selected cameras. This is an approximate value which is calculated based on the pixel clock that
has been set and the data format (bits per pixel). The actual data load on the bus can slightly
deviate from this value.
Input Parameters
hCam
Camera handle
Return Values
INT value
The total current bus bandwidth (in Mbit/s)
Related Functions
is_SetPixelClock()