60 DCx camera
© 2010 Thorlabs
The camera captures an image on the rising edge of the signal applied to the trigger input.
Timeout [ms]
Specifies a timeout for the trigger mode. If the camera does not receive a trigger signal within
this time, a timeout message is transmitted and the transmission error counter is incremented.
Camera
Global Start (Trigger Mode)
If you select this check box, all rows of a rolling shutter sensor are exposed simultaneously.
Activating Global Start only makes sense when using a flash. This function is currently not
supported.
Default
Click this button to reset all parameters to the model-specific defaults.
NOTE
Please note that the frame rate in trigger mode is always lower than in freerun mode.
This is due to the sequential transmission. First the exposure takes place, then the
transfer. A new exposure can only be performed after the transmission is completed.
Therefore, the freerun mode is faster.
High trigger rates are achieved only with short exposure times and a high pixel clock
setting.

Table of Contents

Other manuals for THORLABS DCC1645C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCC1645C and is the answer not in the manual?

THORLABS DCC1645C Specifications

General IconGeneral
BrandTHORLABS
ModelDCC1645C
CategorySecurity Camera
LanguageEnglish

Related product manuals