4 Programming (SDK)
139
Possible cause
Internal error during internal processing of the image
The destination buffers are locked and could not be written
to.
Possible cause/remedy
All destination buffers locked by the application
Release locked destination memory
Allocate more destination memory
Reduce the frame rate so that there is more time to
process the filled destination memory
No free internal image memory is available to the driver.
The image was discarded.
Possible cause/remedy
The computer takes too long to process the images in the
uc480 API (e.g. color conversion)
Reduce the frame rate so that there is more time to
process the filled image memory of the driver
Disable resource-intensive API image pre-processing
functions (e.g. edge enhancement, color correction,
choose smaller filter mask for software color conversion)
The camera is no longer available. It is not possible to
access images that have already been transferred.
Possible cause
The camera has been disconnected or closed.
The image was not transferred over the USB bus.
Possible cause/remedy
Not enough free bandwidth on the USB bus for transferring
the image
Reduce the pixel clock frequency
Operate fewer cameras simultaneously on a USB bus
Check the quality of the USB cabling and components
The maximum allowable time for image capturing in the
camera was exceeded.
Possible cause/remedy
The selected timeout value is too low for image capture
Reduce the exposure time
Increase the timeout
Contents of the uc480_CAPTURE_STATUS_INFO structure
DWORD
dwCapStatusCnt_Total
Returns the total number of errors occurred since
the last reset.
BYTE
reserved[60]
Reserved for an internal function
DWORD
adwCapStatusCnt_Detail[256]
This array returns the current count for each
possible error. The possible errors are listed
above.
Return values

Table of Contents

Other manuals for THORLABS DCU22 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU22 Series and is the answer not in the manual?

THORLABS DCU22 Series Specifications

General IconGeneral
BrandTHORLABS
ModelDCU22 Series
CategorySecurity Camera
LanguageEnglish

Related product manuals