© 2016 Thorlabs Scientific Imaging340
DCx Camera Functional Description and SDK Manual
IS_CCOR_ENABLE_HQ_ENHANCED
When used for monochrome cameras, the system
returns 0.
When used together with
IS_GET_DEFAULT_CCOR_MODE
When used for color cameras and together with
IS_GET_DEFAULT_CCOR_MODE, this parameter
returns the default color correction mode:
IS_CCOR_ENABLE_NORMAL
IS_CCOR_ENABLE_HQ_ENHANCED
When used for monochrome cameras, the system
returns 0.
IS_CANT_COMMUNICATE_WITH_DRIVER
Communication with the driver failed because no
driver has been loaded.
An attempt to initialize or select the camera failed
(no camera connected or initialization error).
Camera is in standby mode, function not allowed
One of the submitted parameters is outside the
valid range or is not supported for this sensor or is
not available in this mode.
An IO request from the uc480 driver failed.
Possibly the versions of the uc480.dll (API) and
the driver file (uc480_usb.sys) do not match.
The camera model used here does not support
this function or setting.
Function executed successfully
Related functions
is_SetColorConverter()
is_SetColorMode()
is_SetAutoParameter()