DCx Camera Functional Description and SDK Manual
Parameter
Description
Value range
Example
and image geometry
Exposure
Current exposure time
Depends on Framerate
0.334059
Long exposure
Activates long exposure
If the long exposure is
active, then the range of
exposure changes.
Not supported by DCx
cameras
0
[Selected Converter]
Sets the type of Bayer conversion for the specified color format when
using color cameras (see is_SetColorConverter()). For a
description of all color formats, see the Color and memory formats
section.
IS_SET_CM_RGB32
Color format
0, 1, 2, 4
2
IS_SET_CM_RGB24
Color format
0, 1, 2, 4
2
IS_SET_CM_RGB16
Color format
0, 1, 2, 4
2
IS_SET_CM_RGB15
Color format
0, 1, 2, 4
2
IS_SET_CM_Y8
Color format
0, 1, 2, 4
2
IS_SET_CM_RGB8
Color format
0, 1, 2, 4
2
IS_SET_CM_BAYER
Color format
0, 1, 2, 4
8
IS_SET_CM_UYVY
Color format
0, 1, 2, 4
2
IS_SET_CM_UYVY_MONO
Color format
0, 1, 2, 4
2
IS_SET_CM_UYVY_BAYER
Color format
0, 1, 2, 4
2
IS_CM_CBYCRY_PACKED
Color format
0, 1, 2, 4
8
IS_SET_CM_RGBY
Color format
0, 1, 2, 4
8
IS_SET_CM_RGB30
Color format
0, 1, 2, 4
8
IS_SET_CM_Y12
Color format
0, 1, 2, 4
8
IS_SET_CM_BAYER12
Color format
0, 1, 2, 4
8
IS_SET_CM_Y16
Color format
0, 1, 2, 4
8
IS_SET_CM_BAYER16
Color format
0, 1, 2, 4
8
IS_CM_RGBA8_PACKED
Color format
0, 1, 2, 4
2
IS_CM_RGB8_PACKED
Color format
0, 1, 2, 4
2
IS_CM_RGBY8_PACKED
Color format
0, 1, 2, 4
8
IS_CM_RGB10V2_PACKED
Color format
0, 1, 2, 4
8
[Parameters]
Additional image parameter settings
Colormode
Sets the current color
mode
see Color and memory
formats
11
Brightness
Software correction of
image brightness
*3
0...255
100
Contrast
Software correction of
image contrast
*3
0...511
215
Gamma
Software correction of the
gamma value
0.01...10.0
1.000000
Hardware Gamma
Sensor-based hardware
correction of the gamma
0, 1
0

Table of Contents

Other manuals for THORLABS DCU22 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU22 Series and is the answer not in the manual?

THORLABS DCU22 Series Specifications

General IconGeneral
BrandTHORLABS
ModelDCU22 Series
CategorySecurity Camera
LanguageEnglish

Related product manuals