4 Programming (SDK)
223
4.3.29 is_FreezeVideo
USB 2.0
USB 3.0
USB 2.0
USB 3.0
Syntax
INT is_FreezeVideo (HIDS hCam, INT Wait)
Description
is_FreezeVideo() acquires a single image from the camera. In DIB mode, the image is stored in the active
image memory. If ring buffering is used in DIB mode, the captured image is transferred to the next available image
m emory of the sequence. Once the last available sequence memory has been filled, the sequence event or
message will be triggered.
In Direct3D or OpenGL mode, the is directly copied to the graphics card buffer and then displayed.
Image capture will be started by a trigger if you previously enabled the trigger mode using
is_SetExternalTrigger() . A hardware triggered image acquisition can be cancelled using
is_StopLiveVideo() if exposure has not started yet.
For further information on the image capture modes of the DCx camera, see the How to proceed: Image capture
section.
Input parameters
hCam
Camera handle
Wait
IS_DONT_WAIT
Timeout value for image capture (see also the How to
proceed: Timeout values for image capture section)
IS_WAIT
Time t
Return values
IS_BAD_STRUCTURE_SIZE
An internal structure has an incorrect size.
IS_CANT_COMMUNICATE_WITH_DRIVER
Communication with the driver failed because no driver has been
loaded.
IS_CANT_OPEN_DEVICE
An attempt to initialize or select the camera failed (no camera
connected or initialization error).
IS_CAPTURE_RUNNING
A capturing operation is in progress and must be terminated before
you can start another one.
IS_INVALID_BUFFER_SIZE
The image memory has an inappropriate size to store the image in
the desired format.
IS_INVALID_CAMERA_TYPE
The camera type defined in the .ini file does not match the current
camera model.
IS_INVALID_EXPOSURE_TIME
This setting is not available for the currently set exposure time.
IS_INVALID_CAMERA_HANDLE
Invalid camera handle
IS_INVALID_MEMORY_POINTER
Invalid pointer or invalid memory ID
IS_INVALID_PARAMETER
One of the submitted parameters is outside the valid range or is not
supported for this sensor or is not available in this mode.
IS_IO_REQUEST_FAILED
An IO request from the uc480 driver failed. Possibly the versions of
the uc480_api.dll (API) and the driver file (uc480_usb.sys) do
not match.
IS_NO_ACTIVE_IMG_MEM
No active image memory available. You must set the memory to
active using the is_SetImageMem() function or create a
sequence using the is_AddToSequence() function.
IS_NO_USB20
The camera is connected to a port which does not support the USB
2.0 high-speed standard.
327
353
134
135

Table of Contents

Other manuals for THORLABS DCU223 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the THORLABS DCU223 SERIES and is the answer not in the manual?

THORLABS DCU223 SERIES Specifications

General IconGeneral
BrandTHORLABS
ModelDCU223 SERIES
CategorySecurity Camera
LanguageEnglish

Related product manuals