MAINTENANCE
ELITE 3000
10.8 REMEDY IN CASE OF FAULTS
Type of malfunction What else? Possible cause Measures for eliminating the malfunction
Unit does not start The device does not start
after it has been plugged
in and switched on.
No voltage applied Check voltage supply
Unit fuse has triggered Let the motor cool down
Capacitor in terminal box
burned out
Replace capacitor
The sprayer was turned o while
still under pressure
Set pressure relief valve to
( circulation).
The sprayer’s thermal protection
has overloaded.
Unplug the power cord, switch the unit off, and
allow the unit to cool.
Unit does not suck in Air bubbles do not exit at
the return hose
Inlet/outlet valve clogged /
worn
Remove the valves and clean then (-> refer to
Section Pkt.10.1/10.2) / replace worn parts
Pressure control valve turned
down completely
Turn the pressure control valve to the right until the
stop is reached
Air bubbles exit from the
return hose
Unit is sucking in outside air Check if Suction system is properly tightened
Check if red inlet is installed in the inlet valve
housing (-> see 4.1)
Check if the inlet valve housing is tightned enough.
Unit does not generate
pressure
Unit has sucked in Air in the oil circuit
(Possible reasons: long time not
used, replacement of diaphragm
or hydraulic oil change
Vent the hydraulic system (-> see 4.6)
Unit reached pressure,
but the pressure
collapses during
spraying.
Suction lter clogged Check the suction lter. If necessary, clean/replace
Paint cannot be worked in this
state. Due to its properties the
paint clogs the valves (inlet
valve) and the delivery rate is
too low.
Dilute the paint
Clogged lter do not let enough
paint pass
Check/clean the (high-pressure lter) gun lter
Tip clogged Clean the tip
Unit does not generate
the max. pressure
possible. Paint
nevertheless exits at the
return hose.
Relief valve defective Please contact Titan Customer Service
After a longer period of
time, the pressure drops
or the performance of the
suction tube decreases
(although all connected
lters are not blocked).
Inlet valve worn Replace inlet valve
Outlet valve worn Replace outlet valve
Tip worn Replace tip

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Titan ELITE 3000 and is the answer not in the manual?

Titan ELITE 3000 Specifications

General IconGeneral
TypeAirless
Spray PatternAdjustable
Max Pressure3000 PSI
Power SourceElectric
Hose Length50 ft
Spray Tip Size0.015 in

Related product manuals