102
Error cord Error description Remedy
Err37 History le open error. Memory card error may occur. Check the memory
card error with the PC.
If the error still remains, it may be eliminated by
reformatting the memory card. But note that all
saved data is erased once the card is reformatted.
Err38 Failed to open the History le.
Err39 Audio le to be played does not exist. Write the project* to the memory card using the EV-
700 Setting software.
Err40 Received command is invalid. Invalid control data may be transmitted to the unit
from the EV-700 Setting software. When an error
frequently occurs, consult the TOA dealer where the
unit was purchased.
Err41 Program of the designated number does not exist.
Err42 Out-of-range value is designated.
Err43 Attempted to execute the 17th sequential storage.
Err44 Abnormality is detected in the priority level
designation.
Err45 Attempted to set abnormal setting values. Abnormal
setting value is conrmed by the Setting storage
memory, setting le, or setting value.
Err46 Time-out occurs during the middle of command
reception.
Control data may be transmitted to the unit from the
EV-700 Setting software at an unintended timing.
When an error frequently occurs, consult the TOA
dealer where the unit was purchased.
Err47 Other command is received before responding to
the received command.
Other command (except the Command control start
command and the Command control end command)
is received before receiving the Command control
start command.
Err51 History storage memory error is detected. The unit's failure may occur. Consult the TOA dealer
where the unit was purchased.
Err53 RTC is reset. The unit's clock is reset. Reset the clock with the EV-
700 Setting software.
When an error frequently occurs, consult the TOA
dealer where the unit was purchased.
Err60 Attempted to make recording to the phrase number
where a phrase is registered. Attempted to make
recording in the state that a le with serial No. 99999
exists.
Make recording by selecting an unregistered phrase
number or after a registered phrase has been
deleted. Recording is not possible when the serial
number of the recorded Audio le reaches 99999.
(As the serial number is automatically assigned to
the phrase at the time of recording on a day-to-day
basis, this error occurs only when the number of
recording per day becomes 100000 or more.)
Err61 Attempted to delete the phrase number to which no
phrase is registered.
To delete the phrase, select the desired phrase
number to which phrase is registered.
Err70 Instruction value used inside the unit's rmware is
abnormal.
The unit's rmware may be malfunctioning. Consult
the TOA dealer where the unit was purchased.
* A collection of les necessary for the EV-700 to broadcast. For the details, read the EV-700 Setting software
instruction manual.